In converged internetworks, Cisco Catalyst switches interact with Cisco IP phones in three different ways. These three different ways are:
- VLAN Tagging
- Extended Trust Settings
- Inline Power Delivery
VLAN tagging is based on the switchport voice vlan interface configuration command, which is described in detail in the ‘Configuring Switches to Support Cisco IP Phones’ section of this chapter. Extended trust settings are based on the switchport priority extend interface configuration command, which is described in the ‘ Catalyst Switch Ingress QoS Mechanisms’ section of this chapter. This section describes inline power.
Cisco IP phones can use an external power cube to draw their power, or they can draw their power from the switch to which they are connected. This power is sent within the Ethernet cable connecting the switch and the IP phone. There are 2 methods for providing inline power:
- IEEE 802.3af-2003
- Cisco Inline Power
IEEE 802.3af-2003 and Cisco Inline Power Overview
IEEE 802.3af-2003 is a ratified version of the original IEEE 802.3af standard. This was ratified in 2003, hence the name 802.3af-2003. The IEEE 802.3af-2003 Power over Ethernet (PoE) standard defines terminology to describe a port that acts as a power source (PSE) to a powered device (PD), defines how a powered device is detected and also defines two (2) methods of delivering Power over Ethernet to the discovered powered device.
IEEE 802.3af power may be delivered using a Power over Ethernet capable Ethernet port, which is referred to as an End-Point PSE or by a mid-span PSE that can be used to deliver Power over Ethernet in the event an existing non-Power over Ethernet capable Ethernet switch is used. The mid-span PSE is described later in this section.
IEEE 802.3af-2003 is an open standard that describes five power classes that a device can belong to. The default power classification within IEEE 802.3af delivers 15.4W per power device. The five 802.3af-2003 power classes are listed in Table 10-9 below.
Table 10-9: IEEE 802.3af-2003 Power Classes
|
Class |
Min. Power Levels Output at PSE |
Max. Power Levels at the PD |
Usage |
|---|---|---|---|
|
0 |
15.4W |
0.44 to 12.95W |
Default |
|
1 |
4.0W |
0.44 to 3.84W |
Optional |
|
2 |
7.0W |
3.84 to 6.49W |
Optional |
|
3 |
15.4W |
6.49 to 12.95W |
Optional |
|
4 |
N/A |
N/A |
Reserved |
Cisco inline power (PoE) is a proprietary approach. The IEEE 802.3af standard is actually based on this method of PoE, which was available before PoE was standardized. Cisco has also extended power management extensions using Cisco Discovery Protocol negotiation to Cisco IEEE 802.3af compliant devices to further optimize PSE power management. Cisco Catalyst switches support both ILP and 802.3af.
Discovering Powered Devices
Before providing power, the switch needs to determine if the port is connected to a power-capable device. Cisco ILP and the IEEE 802.3af-2003 standard use different power detection methods, both of which are supported by the switch.
IEEE 802.3af uses a Direct Current (DC) powered device detection method. Direct Current detect applies a DC current and detects the presence of a powered device by measuring the load applied by the powered device. The switch (PSE) will expect to see a 25 kΩ (Kilo Ohm) resistance between the pairs for the device to be considered a valid powered device. If the PSE does not detect a valid 25 kΩ resistor, power is not applied to the port.
Unlike the IEEE 802.3af standard, Cisco ILP uses Alternating Current (AC) for powered device detection in conjunction with a low pass filter that allows the phone discovery signal to loop back to the switch, but prevents 10/100 or 1000Mbps frames from passing between the receive and transmit pairs. Powered device discovery operates in the following manner for Cisco ILP:
- The switch (PSE) sends a special tone, called a Fast Link Pulse (FLP), out of the port
- The FLP goes to the powered device, such as the Cisco IP phone
- The PD connects the transmit line to the receive line using a low pass filter
- The Fast Link Pulse is looped back to the switch, indicating it is inline power capable
- When the switch receives the returning FLP, it applies power to the line
- The switch port comes up within 5 seconds and the powered device boots
NOTE: The FLP will only be looped back when the PD is unpowered, i.e. has not received power. This allows the switch (PSE) to know that the device requires power.
Inline power (ILP) device discovery is illustrated in Figure 10-13 below.
Figure 10-13: Inline Power Device Discovery
Using either the Cisco ILP or IEEE 802.3af method, if the PD is a Cisco IP phone, it uses Cisco Discovery Protocol to tell the switch (PSE) how much power it wants. The CDP message contains an inline power Type/Length/Value (TLV)that informs the Cisco Catalyst switch (PSE) of the actual power required by the device.
If the power is less than the default 15.4W, the PSE acknowledges the request with its available power and modifies the PSEs power budget. If the requesting powered device exceeds the power budget for the line card or switch, the port is either powered down, or the port remains in low power mode.
Direct Current detection differs from Alternating Current detection in that AC detection transmits a low frequency AC signal (a low-pass filter) and expects the same signal to be received back on the receive pair. DC detect applies a DC Current and detects the presence of a powered device by measuring the load applied by the powered device.
Supplying Power to Power-Capable Devices
Once the powered device has been detected, the PSE needs to supply power. The IEEE 802.3af standard states that power may be delivered by an end-point PSE, using either the active data wires of an Ethernet port or the spare wires, to a powered device. An end-point PSE, such as a Power over Ethernet capable switch, may implement either scheme. It should be noted that even if a device supports both methods of providing power, only one mechanism may be used to deliver power to a powered device.
With the IEEE 802.3af-2003 standard, there are two modes that can be used, which are mode A and mode B. In mode A, pins 1 and 2 form one side of the 48VDC, and pins 3 and 6 form the other side. These are the same pairs used for data transmission. In mode B, pins 4 and 5 form one side of the DC supply and pins 7 and 8 provide the return. These are the unused pairs.
Cisco ILP is provided over the data pairs, as it the case with IEEE 802.3af mode A. The default inline power allocation is 10 W. However, once the inline device is enabled, it will use CDP to adjust its power to the actual requirement. This enables the PD and PSE to negotiate their respective capabilities in order to explicitly manage how much power is required for the device, and also how the PSE-capable switch manages the allocation of power to individual PDs.
Disconnecting Power
The PSE is required to detect when the PD has been disconnected in order to ensure that power is withdrawn from a port before a non-powered device, such as a workstation or laptop, is connected to the switch port.
The IEEE 802.3af-2003 standard defines two mechanisms for disconnecting power once a device has failed. These two methods are DC disconnect and AC disconnect. The DC disconnect method detects when PD current falls below a given threshold (5 to 10 mA) for a given time (300 msec to 400 msec). The AC Disconnect superimposes a small AC voltage on the power and measures the resulting AC current. If the impedance is above 26.25 kΩ (Kilo Ohms), power is shut off. With Cisco ILP, the PoE ports have a power disconnect mechanism that will remove power from the port if the Ethernet link status is down.
Additional Real World Implementation
The IEEE 802.3at-2009 PoE standard, sometimes called “POE+”, provides up to 25.5 W of power, although some vendors have announced products that claim to comply with the new 802.3at standard and offer up to 50 W of power over a single cable by utilizing all 4 pairs in the cable. The IEEE 802.3at-2009 standard also specifies two types of PSEs, which are endspans and midspans. Endspans are simply PoE-capable Ethernet switches, such as Cisco Catalyst 3750, 4500 and 6500 series switches. Midspans are power injectors that stand between a regular switch and the powered device, injecting power without affecting the data. Endspans use pairs 2 and 3, i.e pins 1, 2, 3, and 6, to send power to the PD. These are the data pairs. Midspans use pairs 1 and 4, i.e. pins 4, 5, 7, and 8 to send power to the PD. These are spare pairs. |
While Cisco Catalyst switches support both the IEEE 802.3af-2003 and ILP Power over Ethernet methods, it is important to remember the differences between these two in order to differentiate between them. These differences, which are described in the previous section, are:
- The amount of power that is available to the connected device
- The method used for device discovery
- The way that power is removed from the wire when a powered device is removed
Configuring Power over Ethernet
Cisco PoE-capable Catalyst switches are configured to supply power on a per-interface or per-port basis using the power inline [auto [max <max-wattage>] | never | static [max <max-wattage>]] interface configuration command. By default, in PoE-capable switches, the default is auto (enabled) and the maximum wattage is 15400 milliwatts.
The [max <max-wattage>] allows the administrator to limit the power allowed on the port. The range is 4000 to 15400 milliwatts. If no value is specified, the maximum is allowed. The [never] keyword is used to disable device detection, and disable power to the port.
The [static] keyword is used to enable PD detection and to pre-allocate or reserve power for a switch port before the switch discovers the powered device. This is used when connecting to PDs that cannot communicate with the PSE using any of the discovery methods that are described earlier in this section. These advanced PoE configuration options are beyond the scope of the SWITCH exam requirements and will not be described or illustrated in this chapter.
Verifying Power over Ethernet
The show power inline [interface | consumption default | module switch-number] command is used to display the PoE status for the specified PoE port or for all PoE ports
The [consumption default] option is used to display the power allocated to devices connected to PoE ports. The [module switch-number] keywords are applicable when the switches are stacked together. These keywords can be used to limit the display to ports on the specified stack member. This is beyond the scope of the SWITCH exam requirements. Example 10-27 below illustrates how to verify PoE status using the show power inline command.
Example 10-27: Verifying Power over Ethernet Status
| Catalyst-Switch-1#show power inlineModule Available Used Remaining (Watts) (Watts) (Watts) —— ——— ——– ——— 1 370.0 114.9 255.1 2 370.0 34.3 335.Interface Admin Oper Power Device Class Max (Watts) ——— —— ———- ——- ——————- —– —- Fa1/0/1 auto on 6.3 IP Phone 7910 n/a 15.4 Fa1/0/2 auto on 6.3 IP Phone 7910 n/a 15.4 … [Truncated Output] … |